316 Stainless Steel Cable Glands for Marine Use
Why 316 stainless steel cable glands fail at sea, and what the position of the entry has to do with it. Exposure zones, crevice corrosion, free iron, washdown and installation discipline.
Read More
A split cable gland is a clever solution designed to simplify cable entry, especially for pre-terminated cables—those with connectors already attached. Its core design features three main parts:
Traditional cable glands require disconnecting and stripping cables, making it difficult or impossible to install on cables with fixed connectors. The split body design of these glands enables you to route cables without removing connectors, saving time and reducing the risk of damage.
| Feature | Split Cable Gland | Standard Cable Gland |
|---|---|---|
| Installation | Installed around pre-terminated cables | Requires sliding over cable ends or connector removal |
| Assembly | Quick, tool-assisted assembly | Time-consuming; often requires re-termination |
| Waterproof sealing | IP66/IP68 rated options available | Also available but limited by installation method |
| Ideal for live systems | Yes—can retrofit without downtime | No—must disconnect cables |
| Cable condition | Ideal for pre-terminated or fixed cables | Best when the cable end is accessible |
| Retrofit work | Usually faster and less disruptive | May require disconnection or re-termination |
| Connector preservation | Connector remains attached | Large connectors may not pass through |
| Available configurations | Single- or multi-cable inserts, depending on system | Commonly one cable per gland |
| Cost and simplicity | More components and typically higher unit cost | Often simpler and more economical for new wiring |
While standard glands work well for bare cables, their non-split design limits their use with connectors or live cabling. Waterproof split cable glands overcome this by offering reliable sealing and strain relief for complex setups in industrial, marine, and telecom environments.
A split gland is not automatically the better choice. For a new installation with unterminated cable and no expected changes, a conventional gland is simpler and cheaper to buy. The split construction earns its cost when the connector has to stay on.

A split gland uses a two-part body and a slit elastomer sealing insert. The insert is opened and placed around the cable jacket, then fitted into one half of the body. The two halves close around the insert, and the assembled gland is secured to the enclosure by a thread and locknut, a threaded hole, screws, or a snap-in mechanism, depending on the design.
As the parts close and the pressure screw is tightened, the insert compresses around the cable jacket. That compression does three jobs at once:
What the assembly actually delivers depends on the whole stack — not on the word “split”. Cable outside diameter, insert size, enclosure surface condition, mounting-hole dimensions, gasket condition, tightening torque and product certification all have to line up. That is the reason the size and torque tables below quote a panel cut-out tolerance as well as a clamping range.
Use a split cable gland whenever preserving the cable termination matters more than using the simplest possible entry fitting. Typical situations:
If none of those apply — new build, bare cable, no expected changes — a standard gland is the more economical answer. Our cable gland application areas page covers the wider picture of where each type is specified.
Waterproof split cable glands are a smart choice when you need reliable sealing without the hassle of disconnecting your cables. Here’s why they stand out:
High Ingress Protection: Rated IP66/IP68, these cable glands block dust, dirt, and water even under tough conditions. That means your connections stay safe whether indoors or outdoors.
Strong Strain Relief: They protect cables from pulling or bending forces, reducing the risk of damage or disconnection.
Dust & Moisture Resistance: Essential in harsh environments like marine, industrial, or outdoor setups, keeping your system clean and dry.
Time-Saving Retrofitting: You can route pre-terminated cables without removing connectors, saving hours on installation or maintenance — perfect for live systems.
Preserves Cable Warranty: Since you don’t have to cut or disturb cables, warranties remain valid, and system downtime is minimized.
Ideal for Harsh Environments: Whether it’s saltwater exposure on boats or dust-heavy industrial plants, waterproof split cable glands provide durable, lasting protection.
| Benefit | Description |
|---|---|
| IP Rating | IP66/IP68 for complete dust & water sealing |
| Installation | Quick retrofitting on live cables |
| Strain Relief | Prevents cable damage and loosening |
| Environmental Suitability | Marine, industrial, outdoor harsh conditions |
For marine-specific jobs, consider durable materials like stainless steel — you can find more details about marine-grade solutions in our guide to stainless steel cable glands for marine environments.
Choosing waterproof split cable glands helps you keep your projects running smoothly with less risk and downtime.
The separable construction introduces more sealing interfaces than a one-piece gland, so correct assembly matters more, not less. Compared with an established standard-gland range, split glands also tend to cost more, need a larger mounting footprint, and offer fewer material and certification options.
Check carefully before you specify a split gland for hazardous locations, fire-critical systems, high-pressure washdown, continuous immersion, extreme temperatures, aggressive chemicals, or EMC-sensitive installations. A standard split product does not automatically provide explosion protection, chemical resistance, or 360° shield termination. Each of those requirements has to appear in the manufacturer’s documented specification for the exact model — if it is not in writing, treat it as absent.
Most split gland datasheets read the same, so it is worth knowing which numbers actually separate a gland that still seals in year five from one that weeps at the first maintenance. Below is what we measure — on our own production and on competing split glands that customers send us to benchmark against.
| What we measure | What we typically find on benchmark samples | GHX split cable gland | How we test it |
|---|---|---|---|
| Sealing insert compound | NBR (nitrile) — cheaper, good oil resistance, poor UV and ozone ageing | EPDM, 70 ± 5 Shore A | Shore A durometer plus 1,000 h UV / ozone exposure, then seal check |
| Insert compression set | 30–38 % after 24 h at 70 °C — the insert stops springing back | 18–22 % after the same test | Compression set rig, 70 °C / 24 h, measured to ISO 815 |
| Insert design | Single slit, single lip; a knife-cut seam is common | Moulded single-plane slit with an interlocking double lip | 30 open-and-close cycles, then a full immersion test |
| Body polymer | PA66, frequently with no UV stabiliser declared | PA66 with UV stabiliser, UL94-V0 available | 500 h QUV exposure, then impact test at −20 °C |
| Panel sealing washer | Flat fibre or PVC washer, or none | EPDM profiled washer on a nickel-plated shoulder | Leak check with a deliberately scored enclosure face |
| Thread tolerance | Stated nominal only; no gauge data supplied | 6g tolerance, plug-gauged every production batch | Go / No-Go gauge, in-process, 100 % of batches |
| IP declaration | “IP68”, with no depth and no duration stated | IP68 stated as 2 m / 24 h; IP66 for split inserts on large sizes | Third-party immersion report, supplied per batch |
| Salt-spray performance | Usually not stated | 96 h on plated brass, 500 h on 316L stainless steel | Neutral salt spray to ASTM B117 |
Why EPDM and not NBR. Nitrile is the default for low-cost split glands because it is cheap and resists oil well. But a split gland’s insert sits in a longitudinal seam that is under permanent compression, and NBR takes a compression set — the NBR inserts we have measured from benchmark samples came back at 30–38 % permanent set after 24 h at 70 °C, against 18–22 % for our EPDM. Past roughly 25 % the insert no longer springs back after the pressure screw is loosened for maintenance, and the gland weeps the next time it is tightened. EPDM also holds up far better against UV and ozone, which matters because the insert is the one part of the gland that gets exposed every time someone opens it. The trade-off is oil resistance: for gearbox and hydraulic areas we still mould NBR inserts on request.
The other detail we refuse to compromise on is the seam. A split insert has to be moulded and then cut in a single plane — if it is slit twice, or cut with a hot blade that re-welds the edges, the two faces no longer mate cleanly and no amount of torque will close the gap. Every insert we ship is a single-plane moulded cut, and the tolerance on the mating faces is checked as part of the batch inspection rather than at final assembly.
For demanding installations, our heavy-duty stainless steel PG16 gland carries the same insert design in a 316L body, and nylon models cover the cost-sensitive end of the range without dropping the EPDM insert.
The IP ratings on this page are the ratings we test to, not the ones we hope for. Every batch is checked on our own immersion bench, and any assembly carrying an IP68 declaration ships with a third-party immersion report. The results below are sample-based and only hold when the cable OD sits inside the insert’s clamping range, the panel cut-out is inside tolerance, and the assembly is torqued to the values in the torque table.
| Test | Standard basis | Test condition | Sample | Result |
|---|---|---|---|---|
| IP68 static immersion | IEC 60529 | 2 m depth, 24 h | PA66 split gland M20, single-cable insert, cable OD 6–12 mm | Pass — no water ingress |
| IP68 static immersion | IEC 60529 | 2 m depth, 24 h | Nickel-plated brass PG13.5, cable OD 6–12 mm | Pass — no water ingress |
| IP68 static immersion | IEC 60529 | 2 m depth, 24 h | 316L stainless steel M25, double-lip insert, cable OD 13–18 mm | Pass — no water ingress |
| IP68 after repeated opening | IEC 60529 | Insert seam opened and re-closed 30 times, then 2 m / 24 h | EPDM single-plane moulded insert | Pass — seam faces still mate |
| IP66 water jet | IEC 60529 | 100 kPa, 12.5 L/min, 3 m distance | PA66 PG29 split insert, cable OD 18–25 mm | Pass — large sizes are declared IP66 as standard |
| IP69K high-pressure washdown | ISO 20653 | 80 °C water, 100 bar, 4 positions | 316L stainless steel gland, double-lip insert | Pass |
| Neutral salt spray | ASTM B117 | 96 h | Nickel-plated brass body, assembled | Pass — no white rust |
| Neutral salt spray | ASTM B117 | 500 h | 316L stainless steel body, assembled | Pass — no pitting |
Two things decide whether you actually get IP68 in service. First, the insert must match the cable: an M20 insert that seals 6–12 mm will pass at 10 mm and fail at 5 mm, because the seam never reaches full compression. Second, the panel cut-out tolerance is plus-only (+0.2 / 0) — a hole punched 0.3 mm oversize lifts the sealing washer off the rim and the assembly loses its rating even though every individual component is correct. Both of those failures look identical to a customer: a gland that passed a bench test and weeps in year two.
When choosing a waterproof split cable gland, certain features are essential to ensure reliable performance and durability. Here’s a simple breakdown:
| Rating | Protection Level | Typical Use Case |
|---|---|---|
| IP66 | Dust-tight, powerful water jets | Outdoor equipment, moderate wet environments |
| IP68 | Dust-tight, continuous submersion | Marine, offshore, heavy industrial setups |
The IP rating tells you how well the gland resists dust and water, with IP68 offering the highest sealing for toughest conditions.
A sizing trap worth knowing before you drill: PG13.5 and M20 are often treated as interchangeable, but the cut-outs are not the same — 20.4 mm against 20.0 mm. A PG13.5 gland dropped into a 20.0 mm punched hole still threads, but the sealing washer never reaches full compression around the rim and the assembly will not hold its IP rating. The same applies in reverse for M20 in a 20.4 mm hole. Punch to the thread you actually ordered, and keep the tolerance on the plus side only (+0.2 / 0).
Look for glands with a wide clamping range to fit varying cable sizes, plus multi-hole inserts for sealing several cables in one unit. This helps reduce clutter and improve strain relief according to EN 62444 standards.

The two tables below are the numbers we build to. Panel cut-out is the hole you punch or drill; clamping range is the cable outer diameter the insert will actually seal. Read both before you order — most sizing mistakes come from quoting the thread size and assuming the cut-out.
PG thread series
| Thread | Panel cut-out Ø (mm) | Clamping range — cable OD (mm) | IP rating as supplied | Max panel thickness (mm) |
|---|---|---|---|---|
| PG7 | 12.5 +0.2 / 0 | 3–6.5 | IP68 (2 m / 24 h) | 5 |
| PG9 | 15.2 +0.2 / 0 | 4–8 | IP68 (2 m / 24 h) | 5 |
| PG11 | 18.6 +0.2 / 0 | 5–10 | IP68 (2 m / 24 h) | 6 |
| PG13.5 | 20.4 +0.2 / 0 | 6–12 | IP68 (2 m / 24 h) | 6 |
| PG16 | 22.5 +0.2 / 0 | 10–14 | IP68 (2 m / 24 h) | 6 |
| PG21 | 28.3 +0.2 / 0 | 13–18 | IP68 (2 m / 24 h) | 8 |
| PG29 | 37.0 +0.2 / 0 | 18–25 | IP66 standard / IP68 on request | 8 |
| PG36 | 47.0 +0.2 / 0 | 22–32 | IP66 standard / IP68 on request | 8 |
| PG42 | 54.0 +0.2 / 0 | 30–38 | IP66 standard / IP68 on request | 10 |
| PG48 | 59.3 +0.2 / 0 | 34–44 | IP66 standard / IP68 on request | 10 |
| PG63 | 72.0 +0.2 / 0 | 42–54 | IP66 | 10 |
Metric thread series (M × 1.5)
| Thread | Panel cut-out Ø (mm) | Clamping range — cable OD (mm) | IP rating as supplied | Max panel thickness (mm) |
|---|---|---|---|---|
| M12 × 1.5 | 12.0 +0.2 / 0 | 3–6.5 | IP68 (2 m / 24 h) | 5 |
| M16 × 1.5 | 16.0 +0.2 / 0 | 4–8 | IP68 (2 m / 24 h) | 5 |
| M18 × 1.5 | 18.0 +0.2 / 0 | 5–10 | IP68 (2 m / 24 h) | 6 |
| M20 × 1.5 | 20.0 +0.2 / 0 | 6–12 | IP68 (2 m / 24 h) | 6 |
| M22 × 1.5 | 22.0 +0.2 / 0 | 10–14 | IP68 (2 m / 24 h) | 6 |
| M25 × 1.5 | 25.0 +0.2 / 0 | 13–18 | IP68 (2 m / 24 h) | 8 |
| M32 × 1.5 | 32.0 +0.2 / 0 | 18–25 | IP66 standard / IP68 on request | 8 |
| M40 × 1.5 | 40.0 +0.2 / 0 | 22–32 | IP66 standard / IP68 on request | 8 |
| M50 × 1.5 | 50.0 +0.2 / 0 | 30–38 | IP66 standard / IP68 on request | 10 |
| M63 × 1.5 | 63.0 +0.2 / 0 | 34–44 | IP66 | 10 |
All sizes are produced in UV-stabilised polyamide PA66, nickel-plated brass and stainless steel 304/316L; PG63 is available in PA66 and nickel-plated brass. The clamping range is quoted for the standard single-cable insert — for multi-hole inserts the range is split across the number of bores. A split insert carries a longitudinal seam, which is why the larger sizes are declared IP66 as standard: IP68 is supplied with the double-lip insert and declared with its depth and duration in writing (2 m / 24 h unless we agree otherwise), exactly as described in our guide to how IP ratings are actually tested.
Selecting glands with these features ensures you get robust, long-lasting waterproof split cable glands fit for any application.
The two terms get used loosely, but the products are not the same. A split cable gland is a compact, gland-shaped fitting installed in a round opening and used for one or a small number of cables. A split cable entry system is a larger rectangular or circular frame carrying several modular inserts.
Choose a split gland for a compact entry with a limited cable count. Move to a modular entry frame when many connectorised cables have to pass through a single cut-out, when the configuration is expected to change often, or when cable density is the main design constraint. Everything on this page applies to the gland; the frame systems use the same sealing principle at a larger scale.
Choosing the right waterproof split cable gland starts with knowing your cable size and setup. First, measure the cable diameter precisely, including any connectors if you’re working with pre-terminated cables. Next, consider the number of cables you need to route—single-hole or multi-cable entry glands have different inserts, so pick accordingly.
Check compatible sizing charts to match your cables and glands properly. For example, nylon glands often cover a wide clamping range but may differ from brass or stainless steel options. Using a reliable cable gland sizing chart helps avoid costly sizing mistakes and ensures a perfect fit without damaging cables.
Think about the environment too: gauge the temperature range, possible chemical exposure, and UV stability requirements for your installation. Harsh outdoor or marine conditions need materials that resist corrosion and wear, so materials like stainless steel or brass might be better than nylon in these cases.
Don’t forget compliance standards. Depending on your industry, your cable gland might have to meet UL, NEMA, RoHS, or EN 45545-2 certifications, especially for rail or marine applications. These standards ensure the gland provides reliable strain relief, waterproofing, and safety.
Work through this checklist against your actual drawing before you request a quotation — it is the difference between a first-pass quote and three rounds of samples:
Common mistakes to avoid:
For more detailed guidance, check out this comprehensive guide on how to choose the right IP rating and select cable glands appropriate for your application needs. This helps ensure you get the best waterproof split cable gland that matches your exact requirements.
IP rating and cable gland selection guide
Waterproof cable gland application and selection
Before starting, gather essential tools: an adjustable wrench or spanner, wire strippers, a torque screwdriver, and cleaning cloths. Clean the cable and gland surfaces to remove dust, oil, or debris, ensuring a tight seal. Verify cable diameter and connector type against the gland’s sizing chart for compatibility.
Torque is the single number that decides whether a split gland holds its IP rating in service, and it is the number most often left off a datasheet. The values below are the assembly torques we use on our own production line, measured on a calibrated torque wrench on dry threads at 20 °C. Tighten the body into the panel first, then the pressure screw onto the cable — not the other way around.
| Thread | Spanner flats (mm) | PA66 body (N·m) | Nickel-plated brass (N·m) | Stainless steel (N·m) |
|---|---|---|---|---|
| PG7 / M12 | 15 | 2.5 | 5.0 | 4.0 |
| PG9 / M16 | 18 | 3.0 | 6.0 | 5.0 |
| PG11 / M18 | 20 | 3.5 | 7.0 | 5.5 |
| PG13.5 / M20 | 22 | 4.0 | 8.0 | 6.0 |
| PG16 / M22 | 24 | 5.0 | 10.0 | 7.0 |
| PG21 / M25 | 27–30 | 6.0 | 12.0 | 8.0 |
| PG29 / M32 | 34–40 | 8.0 | 15.0 | 11.0 |
| PG36 / M40 | 43–50 | 10.0 | 18.0 | 13.0 |
| PG42 / M50 | 54–57 | 12.0 | 22.0 | 16.0 |
| PG48 / M63 | 64–68 | 14.0 | 25.0 | 18.0 |

When a gland does fail a leak test, the cause is almost always one of these five — check them in this order before you blame the product:
For extra details on water-tight installation and precautions with brass and stainless steel cable glands, check our waterproof cable gland installation precautions guide.
Waterproof split cable glands are perfect for a wide range of industries where reliable sealing and easy installation are critical. In industrial automation and control panels, these glands provide secure routing of pre-terminated cables, helping reduce downtime during maintenance. They deliver strong strain relief and high ingress protection, ensuring equipment runs smoothly in dusty or wet environments.
For marine and offshore installations, the corrosion-resistant options, such as stainless steel or brass waterproof cable glands, handle harsh saltwater and extreme weather conditions. Their IP66/IP68 ratings guarantee cables stay dry, while split designs allow for retrofitting without disrupting live systems, essential for offshore safety.
In the renewable energy sector, including solar and wind power, split cable glands simplify installation and repairs of multi-cable setups within outdoor enclosures. Telecommunications infrastructure also benefits from split cable glands that protect sensitive connections from moisture and dust, ensuring consistent network performance.
Machinery and robotics environments demand robust cable entry solutions that combine strain relief and EMI shielding. Split cable glands fit well into these setups by accommodating shielded or armored cables, simplifying upgrades, and maintaining compliance with industrial standards.
A real-world example: A manufacturing plant upgraded its control panel wiring using waterproof split cable glands to replace damaged glands without disassembling equipment. This reduced downtime significantly while maintaining IP68 protection, demonstrating how split designs solve practical challenges.
For heavy-duty outdoor applications, browse our selection of stainless steel cable glands for industrial use and brass cable glands designed for industrial automation to find the best fit for your needs.
Keeping your waterproof split cable gland in top shape ensures long-term reliability and protection. Here’s how to maintain and troubleshoot for sustained waterproofing:
Can a split cable gland be installed after the connector is attached? Yes — that is its primary purpose. The body and sealing insert open and close around the cable behind the connector, so the connector never has to pass through the gland.
Can I use one gland for multiple cables? Yes. Multi-cable entry glands are available with multi-hole inserts designed for secure sealing and strain relief of several cables. Every cable must fall inside the range for its own bore, and unused openings must be closed with approved blanks.
Are all split cable glands waterproof? No. Protection ratings vary by model and by assembly. Always check the tested IP or NEMA rating together with the conditions attached to it — cable range, insert type, mounting method and enclosure interface.
Are waterproof split cable glands compatible with armored cables? Only when the product documentation explicitly supports that cable construction and the required armour termination. Many split glands seal the outer jacket only and do not provide the mechanical or electrical functions of an armoured cable gland.
Can split cable glands provide EMC shielding? Only models specifically designed and documented for shield termination should be treated as EMC glands. A metal body on its own does not guarantee continuous, low-impedance contact with the cable screen.
How do I maintain the IP68 rating after installation? Tighten to the recommended torque, check that the sealing insert is seated and the seam is not twisted, and re-check torque after the first 24 hours or the first thermal cycle — PA66 bodies typically need a small top-up.
What information should I send a supplier? Cable outside diameter, connector dimensions, cable quantity, enclosure cut-out and panel thickness, required IP rating, material preference, temperature and chemical exposure, thread standard, strain-relief requirements, and any mandatory approvals. With those in hand we can confirm a model, a price and a lead time in one reply.
A split cable gland is the practical choice when a terminated cable has to enter an enclosure without cutting off its connector. It combines a separable body and a sealing insert to simplify installation while providing cable retention, strain relief and — when specified and assembled correctly — documented environmental sealing.
Choose it from documented cable range, mounting dimensions, protection rating, environment and compliance requirements rather than from thread size alone. That is also how you avoid the two failures we see most often: an insert sized a step too large, and a panel cut-out punched 0.3 mm oversize.
Tell us your cable OD, connector size, cut-out and target IP rating and we will come back with the right configuration — contact us here. If a conventional construction turns out to be the better fit, compare our nylon, brass and stainless steel cable gland ranges instead, and see the cable gland installation guide for preparation and sealing principles.