PG13.5 stainless steel cable gland — 6–12 mm clamping range, 20.4–20.6 mm panel cut-out, 8 mm standard thread length and a 22 mm hex. Body and locknut in 304 or 316L, sealing insert in silicone or EPDM, working range −40 °C to +200 °C.
PG13.5 is the size European machine builders specified for sensor, signal and small power entries for three decades, and it is still the size printed on drawings coming out of those same factories. That is why this gland is bought as a replacement part far more often than as a new design: the panel is already punched at 20.4 mm, the cable is already 8 to 10 mm, and the only open question is whether the body that goes back in should be plated brass or stainless.

PG13.5 is not an M20 — the 0.4 mm that catches everyone
The two sizes are sold as interchangeable in more catalogues than they should be. They are not. The thread outside diameter differs by 0.4 mm, and that is enough to change the hole, the sealing face and the IP result.
| PG13.5 | M20 × 1.5 | PG16 | |
|---|---|---|---|
| Thread O.D. | 20.4 mm | 20.0 mm | 22.5 mm |
| Panel cut-out | 20.4–20.6 mm | 20.0–20.2 mm | 22.5–22.7 mm |
| Cable range | 6–12 mm | 6–12 mm | 10–14 mm |
| Thread length GL | 8 mm | 8 mm | 9 mm |
| Spanner size | 22 mm | 22 mm | 24 mm |
Note the trap in the middle column: the cable range is identical and the spanner size is identical, so everything about the job feels the same until the gland is in the hole. A PG13.5 body dropped into a 20.0 mm punch will start on the thread and then stop short of compressing its sealing washer. It looks installed, it does not seal, and the leak shows up weeks later.
Measure the old gland, not the drawing. The thread size chart lists every cut-out and thread length in both families, and the spanner size chart confirms the hex before you buy a tool.
What “stainless” has to mean on the purchase order
304 and 316L are not interchangeable either, and the certificate is the only place the difference is recorded. Specify 304 for atmospheric and inland exposure, and 316L wherever chlorides, acids or continuous wetting are present — coastal air, food washdown, effluent, de-icing salt. Coastal installations are where 304 fails first, and the failure looks like tea staining before it looks like a hole.
The material is not there to improve the seal. It is there so the seal keeps its compression after the plating on a brass body would have gone. That is why a brass and a stainless gland usually start at the same IP rating and diverge only after two or three years in service. The stainless steel cable gland guide sets the grades and their temperature limits side by side.
Parameter table — PG thread series
The full PG series is listed so you can check a nearest size against the one you are replacing. Metric sizes are on the stainless steel cable gland category.
| Model | Thread | Cable range (mm) | Thread O.D. (mm) | Mounting hole Ø (mm) | Thread length GL (mm) | Bonding length (mm) | Spanner size (mm) |
|---|---|---|---|---|---|---|---|
| PG7 | PG7 | 3–6.3 | 12.5 | 12.5–12.7 | 7 | 19 | 14 |
| PG9 | PG9 | 4–8 | 15.2 | 15.2–15.4 | 8 | 20 | 18 |
| PG11 | PG11 | 5–10 | 18.6 | 18.6–18.8 | 8 | 21 | 20/21 |
| PG13.5 | PG13.5 | 6–12 | 20.4 | 20.4–20.6 | 8 | 22 | 22 |
| PG16 | PG16 | 10–14 | 22.5 | 22.5–22.7 | 9 | 23 | 24 |
| PG19 | PG19 | 10–14 | 25 | 25–25.2 | 9 | 25 | 24/27 |
| PG21 | PG21 | 13–18 | 28.3 | 28.3–28.5 | 9 | 27 | 30/32 |
| PG25 | PG25 | 15–22 | 32 | 32–32.2 | 10 | 29 | 35 |
| PG29 | PG29 | 18–25 | 37 | 37–37.2 | 11 | 31 | 40 |
| PG36 | PG36 | 25–33 | 47 | 47–47.2 | 12 | 37 | 50 |
| PG42 | PG42 | 32–38 | 54 | 54–54.2 | 13 | 38 | 57 |
| PG48 | PG48 | 37–44 | 59.3 | 59.3–59.5 | 14 | 38 | 64 |
| PG63 | PG63 | 42–52 | 72 | 72–72.2 | 15 | 42 | 78 |
Cable range is written ascending here (the catalogue prints it descending). The seal holds anywhere inside that range, but it holds best in the middle third — a cable sitting exactly on the upper limit leaves the insert with almost no compression left to give.
IP68 is a duration, not a badge
The gland is rated IP68 to IEC 60529 in written grades: 1.5 m for 30 minutes, 2 m for 24 hours as standard, 5 m for 72 hours for marine and tunnel work, 10 m for 168 hours by special order. Specify the grade and the test duration on the order, because “IP68” on its own says nothing about how deep or for how long. IP69K, where quoted, refers to high-pressure hot-water jet cleaning and is a separate test, not a better version of IP68.

Installation on a thin panel or a casting
- Check the thread, the cut-out and the cable OD against the table above before the enclosure is opened.
- Fit the body through the hole with its sealing washer, then tighten the locknut. Where an earth tag is used it sits under the body, never over the washer.
- Pass the cable through the dome nut and the insert. The seal works on the sheath — the jacket has to reach the insert seat, so strip to that seat rather than to a copied number. The stripping length guide explains where that point is.
- Tighten the dome nut by hand, then finish to the torque on the datasheet. Stainless takes less torque than brass at the same size, not more.
- Verify by pulling and rotating the cable by hand, and by checking the seal is evenly compressed with no insert extruded from its housing.
On a thin panel the limiting dimension is the 8 mm thread length: a 1 mm washer, a 3 mm panel and a 3 mm locknut already use most of it. On a thick casting the constraint moves to the thread reach, and the answer is an extended thread rather than a different size.
Where PG13.5 is specified
- Sensor, encoder and instrumentation entries on European-built machinery
- Junction boxes and small control enclosures in washdown areas
- Retrofit and maintenance orders where the existing punch is 20.4 mm
- Outdoor and coastal cabinets where a plated body would corrode first
If the cable moves up past 12 mm, the next size is PG29 in stainless steel for feeder work, or PG16 if the cable stays under 14 mm.
Documents, MOQ and quotation
MOQ is 300 pcs per size for stainless steel, because the material and the certificate carry the fixed cost. Trial quantities below that are quoted case by case. Lead time is confirmed on the quotation and depends on grade, thread length and whether a certificate package is required.
Documentation: CE declaration of conformity, RoHS and REACH statements, an IP68 test report to IEC 60529 for the assembly, and a material certificate carrying the alloy grade and the heat number.
Send cable OD, thread and quantity for a same-day price. Samples of 1 to 2 pieces are available for verification.
Request a Quote Now
Our team will get back to you within 24 hours.