A thread size chart answers one narrow question well: for a given thread designation, what is the outside diameter of the thread, what cable will it actually grip, and what hole does it need in the panel. That is three different numbers, and the single biggest cause of wrong orders on this product is treating them as one number.
The chart cannot tell you whether the gland will seal your cable, whether it will hold in your wall thickness, or whether it fits the space next to the terminal block. Those are separate checks. Buyers who read a chart as a shopping list get the thread right and everything else wrong.
Where the hole itself has to be decided — clearance, wall thickness, sealing face and layout — that is covered separately in the cable gland hole size chart.
Below are the full series we manufacture, in the four thread families that cover almost all industrial demand: metric (M), PG, NPT and G (BSPP). Use the tables as reference data, then use the reading method at the end to convert a row into a purchase order.
The Four Thread Families in One View
Metric and PG are both parallel threads sealed at the face of the panel by a gasket. NPT is tapered and seals on the threads. G is parallel like metric but uses a Whitworth thread form with a different flank angle. If that distinction is new to you, the broader explanation lives in our cable gland thread types guide; this page is the numeric companion to it.
Family
Thread form
Seals on
Typical market
Chart columns you must check
Метрическая (M)
ISO 68-1, 60°, parallel, 1.5 mm pitch
Panel face gasket
Europe, Asia, most new projects
Thread O.D., mounting hole, GL
PG
DIN 40430, 80°, parallel
Panel face gasket
Legacy European equipment, older machinery
Thread O.D., mounting hole, GL
NPT
ASME B1.20.1, 60°, tapered
The threads themselves
North America, oil and gas
O.D. at large end, thread engagement length
G (BSPP)
ISO 228-1, 55°, parallel
Face washer or bonded seal
UK, water treatment, marine, HVAC
Thread O.D., hole, sealing washer face
Metric (M) Size Chart — Full Series
All metric glands in this series use a 1.5 mm pitch. Cable range is the clamping range at the sealing insert with the nut fully tightened; the thread outside diameter is what has to pass through the panel; the mounting hole is the drilled or punched opening the gland sits in.
Модель
Нить
Cable range (mm)
Наружный диаметр резьбы (мм)
Mounting hole (mm)
Thread length GL (mm)
Overall length (mm)
Spanner (mm)
M14-NP
M14×1.5
4-8
14
14–14.2
7
19
17
M16-NP
M16×1.5
4-8
16
16–16.2
8
20
18
M18-NP
M18×1.5
5–10
18
18–18.2
8
21
20
M20-NP
M20×1.5
6-12
20
20–20.2
8
22
22
M22-NP
M22×1.5
10–14
22
22–22.2
8
23
24
M24-NP
M24×1.5
10–14
24
24–24.2
9
25
24/27
M25-NP
M25×1.5
10–14
25
25–25.2
9
25
24/27
M28-NP
M28×1.5
13–18
28
28–28.2
9
27
30
M30-NP
M30×1.5
13–18
30
30–30.2
9
29
30/32
M32-NP
M32×1.5
15–22
32
32–32.2
10
29
35
M33-NP
M33×1.5
15–22
33
33–33.2
10
29
35
M36-NP
M36×1.5
18–25
36
36–36.2
10
31
40
M37-NP
M37×1.5
18–25
37
37–37.2
10
31
40
M40-NP
M40×1.5
18–25
40
40–40.2
11
31
40/45
M42-NP
M42×1.5
22–30
42
42–42.2
11
35
45
M48-NP
M48×1.5
25–33
48
48–48.2
11
37
50/52
M50-NP
M50×1.5
32–38
50
50–50.2
12
37
57/55
M63-NP
M63×1.5
37–44
63
63–63.2
13
38
64/68
Note that M24 and M25 share the same cable range, and so do M28 and M30. The step between them buys thread strength and wall clearance, not a bigger cable. If a cable sits at the top of a range, moving up one size class usually fixes grip; moving one thread size up usually fixes nothing.
PG Size Chart — Full Series
PG sizes are not metric sizes with another name. PG13.5 is not M20, PG16 is not M20, and PG21 is not M25 — the outside diameters are close enough to look interchangeable and different enough to fail. The table below is the reference you need when replacing glands on imported machinery built before metric became the default.
Модель
Нить
Cable range (mm)
Наружный диаметр резьбы (мм)
Mounting hole (mm)
Thread length GL (mm)
Overall length (mm)
Spanner (mm)
PG7-NP
PG7
3–6.3
12.5
12.5–12.7
7
19
14
PG9-NP
PG9
4-8
15.2
15.2–15.4
8
20
18
PG11-NP
PG11
5–10
18.6
18.6–18.8
8
21
20/21
PG13.5-NP
PG13.5
6-12
20.4
20.4–20.6
8
22
22
PG16-NP
PG16
10–14
22.5
22.5–22.7
9
23
24
PG19-NP
PG19
10–14
25
25–25.2
9
25
24/27
PG21-NP
PG21
13–18
28.3
28.3–28.5
9
27
30/32
PG25-NP
PG25
15–22
32
32–32.2
10
29
35
PG29-NP
PG29
18–25
37
37–37.2
11
31
40
PG36-NP
PG36
25–33
47
47–47.2
12
37
50
PG42-NP
PG42
32–38
54
54–54.2
13
38
57
PG48-NP
PG48
37–44
59.3
59.3–59.5
14
38
64
PG63-NP
PG63
42–52
72
72–72.2
15
42
78
Both series tables above are our standard brass and stainless steel series. Stainless steel is available in the same size increments; the equivalent PG13.5 body is on the stainless steel PG13.5 product page.
NPT and G Thread Reference
Our standard range is metric and PG. NPT and G glands are quoted to order, so the chart below is the reference data you need to specify them correctly rather than a stock list.
Нить
O.D. (mm)
Threads per inch
Taper
Reading note
1/4″ NPT
13.7
18
1:16
O.D. measured at the large end
3/8″ NPT
17.1
18
1:16
O.D. at large end
1/2″ NPT
21.3
14
1:16
O.D. at large end; will not enter a 20.2 mm hole
3/4″ NPT
26.7
14
1:16
O.D. at large end
1″ NPT
33.4
11.5
1:16
O.D. at large end
1-1/4″ NPT
42.2
11.5
1:16
O.D. at large end
G1/4
13.157
19
Параллель
Needs a face washer to seal
G3/8
16.662
19
Параллель
Face seal
G1/2
20.955
14
Параллель
Same pitch as 1/2″ NPT, different diameter and no taper
G3/4
26.441
14
Параллель
Face seal
G1
33.249
11
Параллель
Face seal
G1-1/4
41.910
11
Параллель
Face seal
G1/2 and 1/2″ NPT are the pair that catches people out. Both are 14 threads per inch, both look the same in a photograph, and a G1/2 male will start into a 1/2″ NPT female for a turn or two before it binds. If the drawing says NPT and the box says G, the joint is wrong even though it screws together. The conversion traps for each family are covered separately in our PG vs metric и NPT vs metric comparisons.
The eight fields on a gland datasheet row. Only the thread column decides fit; the other seven decide whether the part works after it is fitted.
Same Diameter, Different Thread — the Collisions That Cause Returns
The chart exposes something the marketing pages never mention: several metric and PG sizes have an identical outside diameter. When the diameter is the same, the choice comes down to pitch and flank angle, and a part that measures right can still be the wrong part.
Метрика
O.D. (mm)
PG
O.D. (mm)
What happens if you substitute
M25×1.5
25
PG19
25
Same diameter, pitch 1.5 vs 1.41 — the gland starts and then jams
M32×1.5
32
PG25
32
Identical diameter, different pitch; short thread engagement
M37×1.5
37
PG29
37
Identical diameter, different pitch
M20×1.5
20
PG13.5
20.4
PG13.5 is larger — it will not enter a metric hole
M18×1.5
18
PG11
18.6
PG11 is larger — will not enter
M16×1.5
16
PG9
15.2
PG9 is smaller — fits the hole but the gasket cannot cover it
The failure mode differs by direction. A slightly oversize thread will not enter, which is a visible, immediate problem. A slightly undersize thread drops in and looks correct, then leaks past a gasket that has no material under it. The second case is the expensive one, because it is discovered at commissioning or after the first rain.
How to Read the Eight Columns of a Gland Datasheet
A chart row is not a product description; it is a set of constraints. Read it in this order and most specification errors disappear before the order is placed.
Column
What it constrains
Check against
Нить
What the gland screws into
The enclosure entry, not the cable
Cable range
What the seal will grip
Measured cable O.D., not the datasheet of the cable
Диаметр резьбы O.D.
Whether the body passes through the opening
Existing hole or tapped boss
Mounting hole
The opening to cut in the panel
Wall thickness and edge distance
Thread length GL
How much wall the gland can span
Panel thickness plus locknut or gasket
Overall length
Space needed outside the panel
Clearance to doors, ducts, adjacent entries
Spanner size
Access for the tightening tool
Gap to neighbouring components
Model code
The orderable identity of the part
Must appear on the PO with thread and range
The Three Columns Buyers Skip: GL, Overall Length and Spanner
Thread and cable range get all the attention; the length columns cause the field failures. GL runs from 7 mm on the smallest body to 15 mm on PG63. If a gland is going through a thick wall, GL has to cover the wall plus whatever seals on the far side — a locknut, a gasket, a metal tag. A gland with 8 mm of thread in a 6 mm wall leaves almost nothing to engage, and the result is a part that tightens against the wall surface with two threads carrying the load.
Overall length is the opposite constraint: it is the space the gland occupies on the outside, and it is what decides whether the cable can be dressed without a sharp bend right at the entry. On a densely packed enclosure top plate, the difference between a 22 mm and a 29 mm body is the difference between a straight run and a kink.
Thread length has to cover the wall plus whatever seals on the far side. Leave the locknut out of the arithmetic and the engagement disappears.
Spanner size is the column nobody checks until assembly. A 40 mm across-flats nut next to a 30 mm nut on a 32 mm pitch leaves no room for a wrench, and the fitter resolves it by hand-tightening one of them. That gland is now the one that leaks. If the layout is tight, specify a body with a smaller spanner size or move one entry.
From Chart Row to Purchase Order
A correct order line contains four things: the thread designation, the cable range, the material, and the quantity per size. Anything less and the supplier has to guess, and a guess on a gland is usually resolved in the supplier’s favour rather than yours.
Write the range, not a single diameter. “M20, 10 mm cable” is not a specification; “M20×1.5, cable range 6–12 mm, nickel plated brass, 1,000 pcs” is. If the cable is at the edge of a range, say so and ask for the next size up as an alternative — the M20 brass gland and the M25 brass gland overlap in nothing but name; their ranges are 6–12 and 10–14 mm.
For a mixed project, order by size and keep one thread family. Mixing PG and metric on the same panel means two sets of spare parts, two sets of drills and a permanent risk of a wrong-size swap during maintenance. Where the existing panel is PG and the new section is metric, the panel is the thing to standardise, not the gland.
ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ
Is PG13.5 the same as M20?
No. PG13.5 has a 20.4 mm outside diameter on an 80° thread form; M20 has a 20 mm outside diameter on a 60° form with a 1.5 mm pitch. They cover the same cable range in many ranges, which is where the confusion starts, but they do not interchange in a hole.
What size hole does an M20 cable gland need?
20 to 20.2 mm. The chart above gives the mounting hole for every size in the series. Drilling at exactly the thread diameter removes the clearance the gasket needs and makes assembly a press fit.
Which thread should I standardise on for a new project?
Metric. It is the default for new European and Asian equipment, the sizes are in 1.5 mm pitch steps, and the global spare-parts supply is deepest. Keep PG only where an installed base forces you to.
Can I use an adapter instead of ordering the right thread?
You can, and it is sometimes the correct answer for a repair. It adds a joint, adds axial length, and adds a component that nobody records. For new builds, ordering the right thread is cheaper than documenting the conversion.
Does the chart apply to nylon glands too?
The thread diameters and mounting holes are the same, because the thread is cut to the same standard. Cable ranges differ, because nylon bodies use different seal geometry — check a nylon-specific table rather than assuming the brass range transfers.
If you are working from a cable list and a panel drawing, send both and we will return a size-by-size recommendation against the tables above. Our brass и нержавеющая сталь ranges use the same chart, and the cable gland overview covers which family suits which environment.
Откройте для себя высококачественные морские водонепроницаемые кабельные вводы со степенью защиты IP68 из коррозионностойких материалов и простой установкой для надежного использования на море
Являясь важнейшим аксессуаром, соединяющим кабели и оборудование, кабельный ввод играет важную роль в защите кабелей, предотвращении попадания воды и пыли, а также в обеспечении заземления. Будь то промышленная автоматизация, электрическое управление, морские перевозки, добыча полезных ископаемых или другие сложные условия эксплуатации, выбор правильного кабельного ввода имеет большое значение. Сегодня мы рассмотрим основные типы [...].
BW, CW and E1W differ by which cable surface they seal, not by quality. A decision guide based on the two water paths into an enclosure, the location, and the real cost of getting it wrong.
Мы используем файлы cookie для улучшения вашего восприятия, предоставления персонализированной рекламы или контента, а также для анализа нашего трафика. Нажав кнопку "Принять все", вы соглашаетесь с использованием нами файлов cookie.