غدة الكابل are small components, but they sit at every cable entry point in your panel, enclosure or machine, and they do three jobs at once: they hold the cable mechanically, they seal the opening against dust and water, and — depending on the type — they provide earthing or electromagnetic shielding. Specify the wrong gland and the failure usually shows up later: water ingress in an outdoor cabinet, a loose connection after vibration, or an EMC problem in a sensitive control system.
For buyers, the practical question is not “which gland is best” but “which gland family fits my cable, my environment and my budget.” This guide walks through the main types of cable glands, the differences that actually matter when you compare quotes, and the specification details you should prepare before you send an inquiry.
The Main Types of Cable Gland
In practice, cable glands are classified along four dimensions: by structure and sealing mechanism, by the environment they are designed for, by material, and by thread standard. Most products you will see combine features from more than one group — for example, an IP68 waterproof nylon gland with a metric thread.
1. التصنيف حسب الهيكل والوظيفة
غدة كابل ضغط واحدة هذا هو النوع الأكثر شيوعاً، وهو مناسب للبيئات الداخلية والعامة. يستخدم حلقة ضغط واحدة لتأمين الكابل، مما يوفر بنية بسيطة وسهولة التركيب. على سبيل المثال، تعتبر غدة الكابلات ذات الضغط الواحد مثالية لتوصيلات كابل لوحة التحكم - فكر في "غدة الكابل للوحة التحكم".
غدة كابل الضغط المزدوج يوفر هذا النوع مانع تسرب مزدوج على كل من الطبقتين الداخلية والخارجية للكابل، مما يوفر حماية معززة. وهو مثالي للمصانع ومحطات توليد الطاقة والبيئات الأخرى ذات متطلبات الإغلاق والحماية العالية. تمنع غدد الضغط المزدوج بفعالية دخول الغبار والرطوبة من الدخول، مما يضمن سلامة المعدات.
غدة كابل خرطوم مرن مصممة للبيئات ذات درجات الحرارة العالية أو البيئات المعرضة للاهتزازات، حيث يمتص هيكل الخرطوم المرن الإجهاد الميكانيكي ويحمي الكابل من التلف.
غدة كابل PVC غالبًا ما يستخدم هذا الخيار الاقتصادي في كابلات التحكم في الأجهزة، وهو مناسب للبيئات الخفيفة.
2. التصنيف حسب بيئة التطبيق
Standard glands cover most industrial and commercial installations where basic mechanical protection and dust sealing are enough.
Waterproof glands carry a high ingress protection rating — commonly IP68 — and are built for outdoor, marine and communications equipment where water and dust ingress would cause failure. “Waterproof cable gland” and “cable gland IP68” are the terms most buyers search for when they need this category.
Explosion-proof glands are certified for hazardous areas. They prevent flames or sparks from travelling through the cable entry, and they must be matched to the specific zone and standard (ATEX, IECEx) of your site.
EMC glands provide 360° electromagnetic shielding for sensitive equipment such as drives, instrumentation and data communications.
Armoured cable glands are built for steel-wire-armoured (SWA) cables. They clamp the armour layer for mechanical strength and provide electrical continuity for earthing.
3. التصنيف حسب المادة
المواد
الميزات وسيناريوهات التطبيق
نايلون (بلاستيك)
خفيفة الوزن، ومقاومة للتآكل، وفعالة من حيث التكلفة، وعزل جيد.
مقاومة ممتازة للتآكل، مثالية للإعدادات البحرية والكيميائية.
سبائك الألومنيوم
خفيف الوزن مع قوة معتدلة، للاستخدامات الصناعية المحددة.
Nylon Sealing gland are a practical and economical choice for many industrial projects due to their corrosion resistance and insulation. Stainless steel Sealing gland, with their robust protection, are widely used where high protection levels are required. For a closer look at what each material does, see our guide on what a cable gland is.
4. التصنيف حسب معيار الخيط
يؤثر نوع سن اللولب الخاص بتركيبة الكابلات الكهربائية على توافقها مع المعدات أو صناديق التوصيل. وتشمل الأنواع الشائعة ما يلي:
الخيط المتري معيار دولي، يحمل علامة "M20 x 1.5"، ويستخدم على نطاق واسع على مستوى العالم.
يساعد فهم "أنواع خيوط جهاز إحكام غلق الكابلات" على ضمان تطابق الغدة التي تشتريها مع واجهة جهازك بشكل مثالي، مما يجنبك مشاكل التركيب.
الاختلافات الرئيسية بين أنواع غدد الكابلات
Once you compare glands side by side, the differences that matter for procurement are material, waterproof rating, application fit and unit price. The table below compares the main families at typical M20-class sizes. Prices are indicative FOB China figures at mid-volume ordering; actual pricing depends on size, plating, thread and MOQ.
نوع الغدة
Typical Material
تصنيف مقاوم للماء
التطبيق النموذجي
Indicative Price (FOB, 1/pc)
Standard single-compression
PA66 nylon
IP54 – IP66
Control panels, indoor junction boxes, general machinery
$0.11 – $0.21
Waterproof double-seal
PA66 nylon
IP68
Outdoor enclosures, pumps, solar, marine, communication cabinets
Marine, chemical plants, food washdown, coastal facilities
$0.98 – $2.75
EMC shielded
نحاس مطلي بالنيكل
IP67 - IP68
Drives, data centres, sensitive instrumentation
$1.55 – $2.60
مقاوم للانفجار
Brass / 316 stainless steel
IP66 – IP68 + Ex cert.
Oil & gas, chemical plants, mining (ATEX / IECEx zones)
$3.10 – $7.20
Armoured cable gland
Brass / 316 SS / aluminium
IP66 – IP68
Steel-wire-armoured cables, rail, heavy industry
$3.50 – $8.10
Factory-Tested IP Data
A datasheet rating is only useful if it can be reproduced in production. Our in-house test bench verifies ingress protection on production samples in line with IEC 60529 and ISO 20653. Results are sample-based and depend on the cable OD matching the gland’s clamping range and on correct tightening torque.
Test
Standard Basis
Test Condition
Sample
Result
IP68 static immersion
IEC 60529
1.5 m depth, 30 min
PA66 nylon IP68 gland, M20, cable OD 10 – 13 mm
Pass — no water ingress
IP67 immersion
IEC 60529
1 m depth, 30 min
316 stainless steel M20
Pass
IP66 water jet
IEC 60529
100 kPa, 12.5 L/min, 3 m distance
Nickel-plated brass M25
Pass
IP69K high-pressure washdown
ISO 20653
80 °C water, 100 bar, 4 positions
Hygienic 316 SS gland (where offered)
Pass
This is why the cable OD range matters as much as the IP number: an M20 gland rated IP68 still lets water in if the cable measures 8 mm while the gland’s clamping range starts at 10 mm. When you send your actual cable OD, we test and match accordingly.
Key Points for Selecting
A complete selection boils down to five checks. Walk through them before you send an inquiry and you will get a usable quote on the first pass.
IP rating and certifications. Set the IP target from the actual exposure (IP66 for outdoor, IP68 for immersion risk), and check the certifications your market requires — CE, RoHS, REACH, and ATEX / IECEx for hazardous areas.
Cable size and type. Measure the outer diameter of the cable, not the nominal wire size. Note whether the cable is armoured or non-armoured — they need different gland types.
Operating environment. Indoor or outdoor? Is there moisture, salt, chemical vapour or a hazardous-area classification? This decides the IP target and whether you need an Ex-certified or EMC gland.
Material. Match the material to the environment and to lifecycle cost — nylon for economy and insulation, brass for industrial strength, stainless steel for corrosion resistance.
Thread standard. Confirm the thread type and size (metric, PG or NPT) that fits your enclosure so the gland threads in cleanly.
هل ما زلت تتساءل عن كيفية اختيار تركيبات الكابلات الكهربائية؟ لا تتردد في اتصل بنا ! يمكننا التوصية بالحل الأنسب لموصل الكابل الأنسب بناءً على احتياجاتك الخاصة.
قد تكون موصلات الكابلات صغيرة، ولكن دورها بالغ الأهمية. فاختيار "نوع غدة الكابل" المناسب لا يضمن فقط سلامة وثبات نظامك الكهربائي، بل يطيل عمر المعدات ويقلل من تكاليف الصيانة. سواءً كنت بحاجة إلى "مانعة للماء غدة الكابل" للبيئات القاسية أو "غدة الكابلات المدرعة" لحماية الكابلات المدرعة، فإن فهم الاختلافات ونقاط الاختيار أمر ضروري.
Send us your cable OD range, thread standard, material preference and target IP rating. Our engineers will confirm the right gland family, price and lead time in one reply.
الأسئلة الشائعة
ما هي غدة الكابلات ولماذا هي مهمة؟
تركيبات الكابلات الكهربائية عبارة عن جهاز مصمم لتأمين وإغلاق طرف الكابل الكهربائي بالمعدات. تمنع دخول الغبار والرطوبة والملوثات من الدخول، مما يضمن السلامة والموثوقية في التركيبات الكهربائية.
كيف يمكنني معرفة حجم موصل الكابل الذي يجب اختياره؟
قم بقياس القطر الخارجي للكابل الخاص بك وحدد تجهيزة إنهاء الكابل التي تطابق هذا النطاق من المقاس. تحقق دائمًا من ورقة البيانات الفنية للمنتج لمعرفة المقاس الدقيق.
هل يمكنني استخدام غدد الكابلات النايلون في الهواء الطلق؟
إن غدة إدخال الكابل النايلون خفيفة الوزن ومقاومة للتآكل، ولكن للاستخدام الخارجي لفترات طويلة، خاصةً في ضوء الشمس المباشر أو الظروف القاسية، ضع في اعتبارك خيارات الفولاذ المقاوم للصدأ أو النحاس الأصفر لمتانة أفضل.
ما الفرق بين غدد الكابلات أحادية ومزدوجة الضغط؟
غدد ضغط مفردة مانعة للتسرب عند نقطة واحدة وهي مناسبة للبيئات القياسية. توفر غدد الضغط المزدوجة إحكام الإغلاق عند نقطتين، مما يوفر حماية أفضل في البيئات الصعبة أو الخطرة.
What is your MOQ for IP68 nylon glands in M16, M20 and M25?
Standard sizes start at 100 pcs per size, and different sizes can be combined on one order. Custom colors, OEM packaging or non-standard materials adjust the MOQ.
Can you send samples before we order in bulk, and do they cost?
Yes. 1–2 pieces per size can be sent against freight cost, and the sample charge is credited on your first bulk order.
Do you have test reports for the IP rating you quote?
We provide the IP test result sheet from our in-house lab together with CE, RoHS and REACH documentation. For explosion-proof products, tell us the zone and standard you need and we will confirm the certificate on the specific model.
We need nickel-plated brass glands with NPT threads for the US market. Do you stock them?
Yes. Metric, PG and NPT threads run on the same production line, and common NPT sizes are available on short lead times.
What cable OD range does your M20 gland actually clamp?
It varies by model — a typical M20 nylon IP68 gland clamps 6–12 mm. Send us your cable OD and we will match the exact model instead of guessing.
Can you improve the price if we commit to a yearly volume?
Yes — we quote tiered pricing against annual volume. Send your forecast and target price, and we will confirm what is achievable.
في البيئات الصناعية والخارجية الحديثة، تلعب غُدد الكابلات المقاومة للماء دورًا حاسمًا في ضمان سلامة الأنظمة الكهربائية وتشغيلها المستقر. سواء كان ذلك لمحطات الاتصالات القاعدية أو المعدات البحرية أو المصانع الكيميائية والمناجم، فإن غدد الكابلات تحمي الكابلات من الرطوبة والغبار والتآكل وحتى مخاطر الانفجار. خاصة "غُدد الكابلات المقاومة للماء" والكابلات المقاومة للانفجار [...].
نحن نستخدم ملفات تعريف الارتباط لتحسين تجربة التصفح الخاصة بك، وعرض إعلانات أو محتوى مخصص، وتحليل حركة المرور لدينا. بالنقر على "قبول الكل"، فإنك توافق على استخدامنا لملفات تعريف الارتباط.