Stainless steel cable gland PG63 for marine environments — clamping range 42–52 mm, panel cut-out 72.0–72.2 mm, thread length 15 mm, 78 mm across flats. The largest size we produce, and the one where the body has to do structural work as well as sealing.
PG63 is not a scaled-up PG29. At 72 mm of thread and a 78 mm hex, the gland is a load path: the cable it carries is heavy, the panel it enters is often structural, and the tool that tightens it is a large one. Every decision on this page follows from that.

PG63 against M63
The metric size nearest PG63 is M63, and the two are not close enough to substitute. The gap is 9 mm on the thread and 6 mm on the spanner.
| PG63 | M63 × 1.5 | PG48 | |
|---|---|---|---|
| مؤشر الترابط O.D. | 72.0 mm | 63.0 mm | 59.3 mm |
| Panel cut-out | 72.0–72.2 mm | 63.0–63.2 mm | 59.3–59.5 mm |
| Cable range | 42–52 mm | 37–44 mm | 37–44 mm |
| Thread length GL | 15 mm | 13 mm | 14 mm |
| Spanner size | 78 mm | 64 / 68 mm | 64 mm |
If the panel is already punched at 63 mm, no amount of torque will make a PG63 seal in it, and a reducer is not a solution on a marine entry. Confirm the punch diameter before the order is placed — this is the size where getting it wrong means re-cutting a deck plate.
Handling a 42–52 mm cable
At this size the cable is the dominant load. Three things belong in the work instruction and rarely are:
- Support behind the gland. A PG63 entry on a vertical run needs a cable clamp within a short distance, or the gland thread carries the weight of the drop.
- A two-tool assembly. The body hex is 78 mm and the locknut is the same size; holding one while tightening the other needs the right spanners, not an adjustable wrench.
- A dry, burr-free cut-out. A burr under a 72 mm washer is a wider leak path than on any small gland, simply because there is more circumference to leak along.
Parameter table — the top of the PG range
Only the largest sizes are shown. The full PG7–PG63 list, with cut-outs and thread lengths, is on the thread size chart and the spanner size chart.
| الطراز | الخيط | Cable range (mm) | عمق اللولب (مم) | Mounting hole Ø (mm) | Thread length GL (mm) | Bonding length (mm) | حجم مفتاح الربط (مم) |
|---|---|---|---|---|---|---|---|
| PG42-NP | PG42 | 32–38 | 54 | 54.0–54.2 | 13 | 38 | 57 |
| PG48-NP | PG48 | 37–44 | 59.3 | 59.3–59.5 | 14 | 38 | 64 |
| PG63-NP | PG63 | 42–52 | 72 | 72.0–72.2 | 15 | 42 | 78 |
IP68 on a deck main feeder
Specify 5 m / 72 h rather than the standard 2 m / 24 h for deck and bulkhead work, and put the duration in the purchase order. The 316L body is there so the seal keeps its compression after years of salt exposure; it does not improve the seal itself, and it will not rescue a joint assembled onto a scored panel face.
Documents, MOQ and quotation
MOQ is 300 pcs per size for stainless steel. PG63 is a schedule item rather than a stock item on most projects, so lead time is confirmed per order and depends on grade and thread length. Documentation: CE, RoHS and REACH statements, an IP68 test report to IEC 60529, and a 316L material certificate with the heat number for class survey.
Send cable OD, thread and quantity for a same-day price. Samples of 1 to 2 pieces are available for verification.
اطلب عرض أسعار الآن
سيقوم فريقنا بالرد عليك خلال 24 ساعة.