GHX Cable Gland Overview: Robust, Certified Solutions for Hazardous Areas
GHX cable glands deliver superior performance as explosion proof cable glands designed for secure, reliable cable entry in demanding hazardous and industrial environments. Engineered to meet the highest standards, these armoured cable glands ensure exceptional sealing with IP66/IP68 ingress protection ratings, robust armour clamping, and excellent corrosion resistance across a wide range of cable diameters.
Trusted worldwide, GHX glands comply fully with global safety standards including IEC, NEC, and CEC, making.
Key Features & Advantages of CMP Cable Glands
GHX CMP cable glands stand out with robust features designed for tough industrial use:
Triple/Dual Certification Certified for Ex db (flameproof), Ex eb (increased safety), Ex nR (non-sparking), and Ex ta (protection by enclosure), ensuring reliable performance in hazardous zones.
Premium Materials Available in brass, nickel-plated brass, stainless steel, and aluminium, offering options tailored to different environmental demands and corrosion resistance needs. For example, our corrosion-resistant stainless steel cable glands handle marine and chemical exposure flawlessly.
Independent Inner & Outer Seals Dual seal design locks out dust, water, and chemicals separately, enhancing protection beyond typical IP66/IP68 ratings.
360° Armour Grounding & High Pull-Out Resistance Ensures total armoured cable conductivity and secure clamping, vital for safety and mechanical stability.
Wide Temperature & Vibration Resistance Performs reliably from -60°C to +130°C and withstands harsh vibrations, ideal for mining, oil & gas, and petrochemical sectors.
الميزة
المزايا
Ex db, Ex eb, Ex nR, Ex ta
Certified for hazardous areas
Brass, Stainless Steel, etc.
مقاومة التآكل والمواد الكيميائية
Inner/outer seals
Superior environmental protection
360° armour grounding
Reliable earthing & strength
Wide temperature range
Use in extreme environments
These top-tier features make GHX cable glands the trusted choice for secure, durable cable entry in demanding, hazardous industrial settings.
Product Specifications for CMP Cable Gland
Our GHX CMP cable glands come with a variety of thread types and sizes to fit your industrial needs:
نوع الخيط
الوصف
متري
Popular choice for international use (e.g., M16, M20)
NPT
Tapered threads common in North America
PG
Common in European applications
G/BSP
Parallel threads, widely used globally
Cable Acceptance Ranges
Armour Diameter: Suitable for SWA, AWA, PWA, wire braid, and tape armour cables
Overall Diameter: Accommodates a wide range of cable sizes, ensuring a tight fit and reliable seal
Ingress Protection Ratings
IP66: Dust tight and protected against powerful water jets
IP67: Protected against temporary immersion in water
IP68: Complete dust protection and long-term immersion capability for marine or harsh environments
Where applicable, we also offer deluge protection and marine certifications for extreme conditions.
Hazardous Area Classifications
The GHX CMP cable glands meet strict standards for explosive environments:
Zones 1 & 2: Gas environments
Zones 21 & 22: Dust environments
Gas Group: IIC (includes hydrogen, acetylene – the most demanding gases)
Technical Data at a Glance
Size
Weight (g)
Torque (Nm)
Cable Ø Range (mm)
Armour Ø Range (mm)
M16
50
4.5
4–10
3–8
M20
70
6
6-12
4–10
PG42
150
15
20–32
15–25
NPT 1”
140
12
19–29
12–20
These values vary by material and specific model.For applications needing stainless steel durability in hostile conditions, check our stainless steel cable gland PG63 designed specifically for marine environments.Our CMP explosion proof cable glands bring versatile thread options, wide cable compatibility, and industry-leading ingress protection to keep your installations safe and reliable.
توافق الكابلات
GHX CMP cable glands are designed to handle a broad range of cable types, ensuring secure and reliable connections for any industrial setup. They work perfectly with armoured cables like SWA (Steel Wire Armour), AWA (Aluminium Wire Armour), PWA (Polypropylene Wire Armour), along with wire braid, aluminium strip, and tape armour varieties. For projects using unarmoured or tray cables, flexible cords, MC-HL, or Teck90 cables, these glands provide excellent sealing and strain relief.Additionally, lead-sheathed or braided cables are fully compatible, making GHX glands a versatile choice across multiple installations. This wide cable acceptance range accommodates various armour diameters and overall cable sizes, securing connection integrity in hazardous and demanding environments.For detailed insights on thread compatibility and sizing, you might find our comprehensive guide on different cable gland thread types useful to ensure the proper fit with your cable system.
Certifications & Compliance
GHX CMP cable glands come fully certified to meet the strictest industry standards, ensuring safe and reliable use in hazardous and industrial environments worldwide. Our explosion proof cable glands hold ATEX and IECEx approvals, confirming their suitability for gas and dust hazardous zones. They also carry UKCA, cCSAus, UL, and FM certifications, covering key global markets.
For marine and offshore applications, GHX glands are approved by major classification societies such as Lloyd’s Register, DNV, and ABS, demonstrating robust deluge and saltwater resistance. These approvals make GHX cable glands the trusted choice for oil & gas, petrochemical, and mining sectors.
We comply with international standards including IEC 62444, EN 62444, and BS 6121 for cable gland design and testing, giving you full confidence in product performance. Downloadable certificates and detailed test reports are readily available to support your project documentation and audits.
Choose GHX for a certified, high-quality armoured cable gland that ensures safety and compliance without compromise.
Installation Guide for CMP Cable Gland
Installing your GHX CMP cable gland properly is key to ensuring reliable performance in hazardous and industrial environments. Here’s a straightforward breakdown to get you started safely and efficiently:
Step-by-Step Instructions
جهز الكابل: Strip the outer sheath carefully to expose the armour or braid without damaging it.
Insert the Gland: Slide the gland over the cable, ensuring it matches the cable diameter and armour type.
Armour Termination: Firmly clamp the armour using the gland’s 360° armour grounding feature for a secure connection.
Seal Tightening: Tighten the gland using recommended torque settings — too loose may cause leaks, too tight can damage the seal.
Make-Off Procedures: Whether direct or remote make-off, ensure the inner and outer seals are properly compressed for IP66/IP68 waterproofing.
Tools and Torque Settings
Use calibrated torque wrenches for tightening to avoid under or over-tightening.
Follow provided data sheets for specific torque values related to your gland size and thread type.
Safety Notes for Hazardous Areas
Always comply with your local hazardous zone regulations when installing explosion proof cable glands.
Confirm that the gland’s certification matches the hazardous area classification (e.g., ATEX Zone 1 or Zone 21).
Use proper personal protective equipment (PPE) during installation.
Avoid contaminating the sealing surfaces; clean tools and hands help maintain certification integrity.
For detailed exploded views and best practices on waterproof cable gland installation, visit our comprehensive guide on installing waterproof cable glands.
Following these steps ensures your GHX cable gland maintains its superior environmental protection, strong armour clamping, and overall secure cable entry in critical industrial applications.
Applications & Industries
GHX CMP cable glands are designed to perform in the toughest environments across a wide range of industries. You’ll find them trusted on oil & gas platforms and refineries, where explosion proof cable glands are essential for safety. They’re ideal for petrochemical plants and mining operations too, handling harsh, hazardous conditions with ease.
Marine and offshore sectors rely on these glands for their corrosion resistance and waterproof capabilities—perfect for saltwater exposure. In construction, pharmaceuticals, and transportation, their robust armour clamping and environmental seals make them dependable for both indoor and outdoor use.
These cable glands also excel in explosive gas and dust environments, meeting global standards to deliver secure, safe cable entry where it matters most. For marine-specific needs, you might also explore our stainless steel cable gland for outdoor applications designed to withstand severe weather conditions.
Comparison / Why Choose GHX CMP Cable Glands
When it comes to CMP cable glands, GHX stands out for several solid reasons. Compared to standard CMP-style glands, GHX offers enhanced durability, robust sealing, and better overall protection—without breaking the bank. Here’s a quick breakdown:
الميزة
GHX CMP Cable Gland
Standard CMP Gland
Generic/Non-Certified Glands
Sealing Level
Superior IP66/IP68 sealing
Basic IP65–IP66
Often poor or unverified
Material Quality
Brass, nickel-plated, stainless steel, aluminium
Usually lower-grade metals or plastics
Varies, often subpar
التصديق
Triple/dual certified (Ex db, Ex eb, Ex nR, Ex ta)
Limited or no hazardous area certification
Rarely certified
Armour Clamping & Grounding
360° armour grounding, high pull-out resistance
Basic clamping, limited grounding
Often lacks proper armour support
Chemical & Vibration Resistance
High resistance across wide temperature ranges
Moderate resistance
Typically minimal
Pricing
Competitive for certified quality
Sometimes cheaper but less durable
Cheapest, but risky
Why Choose GHX?
Reliable in Hazardous Areas: GHX glands comply with ATEX, IECEx, and other global standards, ensuring safety in explosive gas or dust environments.
Long-Term Performance: Materials and design reduce corrosion, mechanical wear, and environmental damage.
Versatility: Compatible with a wide cable range including armoured cables like SWA and flexible cords.
فعالة من حيث التكلفة: You get premium features and certification without a premium price tag.
In short, GHX CMP cable glands deliver peace of mind—robust, certified, and priced right—making them the smart choice over generic or non-certified alternatives.
Related Products & Accessories
To complement our robust CMP cable glands, we offer a range of related products and accessories designed for seamless installation and enhanced performance. These include adaptors and reducers to fit various thread sizes, locknuts for secure mounting, and earth tags to ensure proper grounding. Shrouds provide additional protection against mechanical damage and weather exposure.
For more demanding environments, our barrier glands with compound seals offer extra protection against harsh chemicals and moisture, maintaining the integrity of explosive-proof cable entry points. We also supply cleats and fixing accessories to keep cable runs tidy and secure, reducing strain and vibration on the cable glands.
Q: How do I choose the right CMP cable gland for my application?
Look for glands that match your cable type (armoured or unarmoured), size, and environmental needs. GHX cable gland options cover a wide cable range with IP66/IP68 sealing, making them suitable for hazardous area and industrial setups. Check certifications like ATEX or IECEx for compliance with safety standards.
Q: Are GHX cable glands compatible with different cable armours?
Yes, GHX gland designs support SWA, AWA, PWA, wire braid, and aluminium strip armour types, as well as flexible cords and tray cables. This versatility ensures secure clamping and reliable grounding.
Q: How should I maintain explosion proof cable glands?
Regular inspections for mechanical damage, corrosion, and seal integrity are essential. Clean the gland area and retighten connections as needed, using the recommended torque values. Follow local hazardous area safety procedures during maintenance.
Q: Can I use GHX cable glands in marine or outdoor settings?
Absolutely. Many GHX cable glands offer marine approvals and high ingress protection (IP68), ensuring waterproof and corrosion-resistant performance in harsh environments.
Q: What certifications should I check for?
Key certifications include ATEX, IECEx, UKCA, cCSAus, UL, and FM. Marine classifications like Lloyds and DNV may also be relevant. Always verify that the gland’s certification matches your zone classification and gas group.
Access all essential documents to get the most from your CMP cable gland solutions. Our downloadable resources include:
Detailed datasheets with product dimensions, materials, and performance specs
Comprehensive catalogues featuring the full range of GHX explosion proof cable glands and related accessories
Step-by-step installation manuals to guide correct fitting and maintenance in hazardous areas
Precise STEP files for CAD integration and engineering design
Official certificates confirming compliance with ATEX, IECEx, UKCA, and other key standards
These resources ensure you have everything needed for smooth project planning, compliance checks, and safe deployment of your industrial cable entry devices. For stainless steel solutions designed for tough environments, explore our options like the heavy duty stainless steel cable gland PG16 or the PG21 stainless steel cable gland with metric thread to match your specifications precisely.
Get in Touch for Your CMP Cable Gland Needs
Ready to secure your cables with reliable, certified GHX cable glands? Reach out to us anytime through our easy enquiry form for fast quote requests or technical support. Whether you need advice on choosing the right explosion proof cable gland or detailed installation guidance, our expert team is here to help.
Use our live chat for instant answers or find a local distributor near you to get your armoured cable gland fast and hassle-free. Don’t compromise on safety and durability — contact GHX for trusted hazardous area cable gland solutions tailored to your industrial or marine projects.
Start your request now at our contact page, and let’s secure your cable entry points the right way.
كملحق أساسي لتوصيل الكابلات والمعدات، تلعب غدة الكابلات دورًا حيويًا في حماية الكابلات ومنع دخول الماء والغبار وتوفير التأريض. سواءً في الأتمتة الصناعية أو التحكم الكهربائي أو البحرية أو التعدين أو غيرها من البيئات الصعبة، فإن اختيار غدة الكابلات المناسبة أمر ضروري. اليوم، دعونا نلقي نظرة فاحصة على الأنواع الرئيسية [...].
هل عانيت من قبل في اختيار غدة الكابل المناسبة؟ لا تقلق - لست وحدك! قد تكون غدة الكابلات صغيرة، ولكنها تلعب دوراً رئيسياً في ضمان سلامة واستقرار أنظمتك الكهربائية. سواءً كنت تعمل في مجال الأتمتة الصناعية أو البتروكيماويات أو الهندسة البحرية، فإن اختيار غدة الكابلات الخاطئة يمكن أن يؤدي إلى تسرب المياه أو قصر [...].
نحن نستخدم ملفات تعريف الارتباط لتحسين تجربة التصفح الخاصة بك، وعرض إعلانات أو محتوى مخصص، وتحليل حركة المرور لدينا. بالنقر على "قبول الكل"، فإنك توافق على استخدامنا لملفات تعريف الارتباط.