Prensaestopas de nylon

Prensaestopas de nylon estándar

El prensaestopas de nylon está fabricado con material de poliamida 6 (nylon) con arandela, junta y contratuerca para garantizar el grado de protección IP68. Prensaestopas de nylon con alivio de tensión integrado diseñado en diferentes tipos de colores como el rojo, amarillo, lo que significa que puede clasificar los cables para diferentes aplicaciones.

Hilo:Métrico | PG | G(PF) | Rosca NPT
Materiales:Caucho PA6,EPDM para piezas B.D
Junta y anillo de estanqueidad:NBR,Goma de silicona
Nivel de protección:Barra IP68-10
Temperatura de trabajo:-40℃ a 100℃ en estado estático, o resistencia térmica instantánea de hasta 120℃. -20℃ tosocin estado dinámico, o resistencia térmica instantánea hasta 100℃.

Prensaestopas de nylon estándar

Thread systemsMetric, PG, G(PF), NPT
Body materialPolyamide; EPDM seal on the clamping parts
Protection degreeIP68 to 10 bar
Working temperature−40 °C to +100 °C static; +120 °C short-term
ColoursBlack RAL 9005, grey RAL 7035; other colours on request

Standard Nylon Cable Gland 1

The default gland, in the widest range we mould

This is the straight-through, one-cable, one-hole gland. It has no split body, no elbow and no extended thread, and that is the point: it covers the entries that are not special in any way, from M12 up to M114.

It is the right part when four conditions hold at once. The cable is unterminated when it reaches the panel. The entry is straight. The wall build-up is under 9 mm. And the cable sits inside the stated range rather than on its edge. Most panel work meets all four.

Where it is the wrong part

Each of the other four nylon products on this site exists because one of those conditions fails. If the connector is already fitted, a one-piece gland cannot be installed and the divided-structure gland is the substitute. If the wall plus locknut and washer exceeds 9 mm, the longer-thread version gives 15 mm. If the cable has to turn at the wall, the 90° elbow does it. And if the shield needs bonding to the enclosure, none of them will do it — that requires the EMC gland.

Standard Nylon Cable Gland 5

ModeloD.E. de la rosca
(mm)
Tamaño del orificio
(mm)
Longitud de la rosca
(mm)
Grosor del cuerpo
(mm)
Gama de cables
φ(mm)
Tamaño de la llave
A&F(mm)
N-M12M12×1.5φ12.2-12.5933~6.518/16
N-M16M16×1.5φ16.2-16.5934~822/19
N-M18M18×1.5φ18.2-18.5935~1024/22
N-M20M20×1.5φ20.2-20.5956~1227/24
N-M22M22×1.5φ22.2-22.510510~1430/27
N-M24M24×1.5φ24.2-24.510512~1533/28
N-M25M25×1.5φ25.2-25.510513~1533/28
N-M25M25×1.5φ25.2-25.512513~1833/30
N-M25M25×1.5φ25.2-25.51259~1633/33
N-M27M27×1.5φ27.2-27.512513~1835/33
N-M30M30×1.5φ30.2-30.512616~2137/37
N-M32M32×1.5φ32.2-32.512616~2139/35
N-M36M36×1.5φ36.2-3712618~2545/42
N-M40M40×1.5φ40.2-4117722~3052/52
N-M50M50×1.5φ50.5-51191032~3860/60
N-M63M63×1.5φ63.5-64191037~4474/69
N-M72M72×1.5φ72.5-73271045~5088/78
N-M75M75X276261045-5088/78
N-M80M80X281281160-7090/97
N-M88M88X289281160-7098/97
N-M100M100X2102291180-90110/115
N-M114M114X2116291180-90122/115

Three checks before the order goes out

  1. Cable OD inside the range, with margin. A 12 mm cable in a 6–12 mm M20 entry is on the limit and will seal poorly. Step up to M25.
  2. Hole size from the table, not from the thread. M20 needs 20.2 to 20.5 mm. A 20 mm hole will not accept the thread.
  3. Thread length against wall build-up. Wall, locknut and sealing washer must add up to less than the thread length, with two or three threads left for the nut.

For outdoor entries, specify the black UV-stabilised moulding. The grey and natural grades are for indoor panels where sunlight never reaches the entry.

Size bands: what changes between M12 and M114

The table above covers four decades of cable diameter in one series, and the engineering problem is different in each band. Buyers who treat M12 and M63 as the same decision usually get one of them wrong.

BandTypical cable ODWhat actually decides the choice
M12–M203–12 mmEntry density. At 3 mm body thickness the gland is slim, but spanner clearance between adjacent holes becomes the limiting factor, not the gland.
M22–M4010–25 mmSeal squeeze. The cable must sit inside the stated range; going one size up to “leave room” is the single most common cause of a weeping entry.
M42–M6322–44 mmAccess. The dome nut needs a full spanner swing, so the entry has to be laid out with tool clearance in mind.
Above M6356–90 mmAvailability. Large sizes are not held at the same depth as stock sizes, and the mounting hole (over 100 mm at M100) is a fabrication decision, not a purchasing one.

Two practical notes on reading the table above. Some models list a second cable range on a continuation row — that is the same thread with a different insert, so the model code matters as much as the size. And the hole size column already includes the clearance: an M20 needs 20.2 to 20.5 mm, not 20 mm.

Installing across the range

The sequence does not change with size, but the acceptance criterion does. On M12 to M20, hand-tight plus a quarter turn is usually enough and the risk is cracking the body by over-tightening. On M42 and above the seal needs real torque, and the check is whether the insert has compressed evenly around the sheath rather than whether the nut feels tight. Torque values by size are on the datasheet.

Where the entry is outdoors, the black UV-stabilised grade is the one to specify; the natural and grey grades are for indoor panels. The IP rating guide explains what the sealed assembly can and cannot claim once installation is finished.

Where the series is used

  • Control panels and junction boxes, where M16 to M25 covers most entries
  • Machine wiring and sensor runs at M12 to M16
  • Outdoor lighting and PV combiner boxes in the UV-stabilised black grade
  • Distribution and telecom cabinets at M32 to M63

Ordering by band

Standard sizes are 1,000 pcs per size for factory pricing with no tooling charge; trial orders from 100 to 500 pcs. Above M63, confirm the size and quantity before the enclosure drawing is released, because the hole changes with it. Quote the model code rather than the thread alone — several threads carry two cable ranges.

Send the model code, cable OD and quantity for a same-day price. Samples of 1 to 2 pieces are available.

Solicite un presupuesto ahora

Nuestro equipo se pondrá en contacto con usted en un plazo de 24 horas.